The term "public lift" means the type of lift designed and made for public use buildings, like schools, hospitals, and the community in general.
The characteristics of these lifts are regulated by the following laws: Italian Presidential Decree 503/86, containing rules for the elimination of architectural barriers in buildings, spaces and public services, based on European Directive EN 81.70, inherent to accessibility of people, including disabled ones, and lastly on the Lombardy Region Law n. 6/89.
Minimum values of the aforementioned regulation are listed in the below table.
Lombardy Region Law n.6 of 20-02-89 and EN 81.70
Number of entrances
Door width
(mm)
Person load
(kg - person)
Cab dimensions (mm)
1
2 opposti
2 adiacenti
1
2 opposti
900
900
900
900
900
860 - 11
860 - 11
1000 - 13
1275 - 17
1275 - 17
1370 x 1500
1500 x 1500
1400 x 1400
2000 x 1400
2000 x 1400
Italian Presidential Decree n. 503 of 24-07-96
Type of
building
Number of entrances
Door
width (mm)
Person load
(kg - person)
Cab dimensions (mm)
Ristrutturazione
Nuovo residenz.
Nuovo non resid.
1-2-3
1-2-3
1-2-3
750
800
800
360 - 4
480 - 6
630 - 8
800 x 1200
950 x 1300
1100 x 1400
suited to overcoming architectural barriers.
download technical sheets (PDF)
The designs presented in the PDF files below are only examples and they always show the minimum measurements and loads of various regulations.
The designs with measurements and superior loads are available on request: write to info@rerman.it