lifts - residenziali - ristrutturazione
description
The term renovation means a construction intervention which wholly or partly modifies an existing building. On this page we take into consideration the installation of lifts in renovation of residential buildings, meaning with end use is housing.

The characteristics of these lifts, which are regulated by Law 13 of 1989 and by Ministry of Public Works Decree 236 of 1989, are reported in the table below.
Number of
entrances
Door
width (mm)
Person load
(kg - person)
Cab
dimensions (mm)
Hoistway
size (mm)
1
2 opp.
2 adj.
3
750
750
750
750
360 - 4
360 - 4
580 - 7
580 - 7
800 x 1200
800 x 1200
1200 x 1200
1200 x 1200
1350 x 1550
1350 x 1750
1600 x 1900
1860 x 1740
   suited to overcoming architectural barriers.
download technical sheets (PDF)
The designs presented in the PDF files below are only examples and they always show the minimum measurements and loads of various regulations.
The designs with measurements and superior loads are available on request: write to info@rerman.it

electric: gearless:
- sole access - sole access
- double opposite access - double opposite access
- double adjacent access - double adjacent access
images
preview images